<?xml version="1.0" encoding="UTF-8"?>
<!-- generator="FeedCreator 1.8" -->
<?xml-stylesheet href="https://sermn.uab.cat/wiki/lib/exe/css.php?s=feed" type="text/css"?>
<rdf:RDF
    xmlns="http://purl.org/rss/1.0/"
    xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
    xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
    xmlns:dc="http://purl.org/dc/elements/1.1/">
    <channel rdf:about="https://sermn.uab.cat/wiki/feed.php">
        <title>SeRMN Wiki problemes_tecnics_sermn</title>
        <description></description>
        <link>https://sermn.uab.cat/wiki/</link>
        <image rdf:resource="https://sermn.uab.cat/wiki/lib/tpl/dokuwiki/images/favicon.ico" />
       <dc:date>2026-05-03T04:23:01+00:00</dc:date>
        <items>
            <rdf:Seq>
                <rdf:li rdf:resource="https://sermn.uab.cat/wiki/doku.php?id=problemes_tecnics_sermn:20071116_robot_es_penja"/>
                <rdf:li rdf:resource="https://sermn.uab.cat/wiki/doku.php?id=problemes_tecnics_sermn:20071119_no_acq_hardware"/>
                <rdf:li rdf:resource="https://sermn.uab.cat/wiki/doku.php?id=problemes_tecnics_sermn:20071119_reajust_field"/>
                <rdf:li rdf:resource="https://sermn.uab.cat/wiki/doku.php?id=problemes_tecnics_sermn:20080229_canvi_ventiladors"/>
            </rdf:Seq>
        </items>
    </channel>
    <image rdf:about="https://sermn.uab.cat/wiki/lib/tpl/dokuwiki/images/favicon.ico">
        <title>SeRMN Wiki</title>
        <link>https://sermn.uab.cat/wiki/</link>
        <url>https://sermn.uab.cat/wiki/lib/tpl/dokuwiki/images/favicon.ico</url>
    </image>
    <item rdf:about="https://sermn.uab.cat/wiki/doku.php?id=problemes_tecnics_sermn:20071116_robot_es_penja">
        <dc:format>text/html</dc:format>
        <dc:date>2007-11-19T12:27:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>problemes_tecnics_sermn:20071116_robot_es_penja</title>
        <link>https://sermn.uab.cat/wiki/doku.php?id=problemes_tecnics_sermn:20071116_robot_es_penja</link>
        <description>Avance DPX-250 + BACS

2007-11-19 - El robot es penja sovint

Des de mitjans d'octubre la freqüència d'aturades del robot s'ha incrementat notablement, fins el punt de que moltes nits i caps de setmana no es poden aprofitar. El dia 2007-11-16 ens vàrem estar mirant el problema amb l'Óscar. Després de comprovar que tot funcionava correctament, vàrem intentar reproduir el problema sense aconseguir-ho, fins i tot programant solvents incorrectes o posant-hi un tub buit. El cas és que aquell dia el r…</description>
    </item>
    <item rdf:about="https://sermn.uab.cat/wiki/doku.php?id=problemes_tecnics_sermn:20071119_no_acq_hardware">
        <dc:format>text/html</dc:format>
        <dc:date>2007-11-19T12:43:19+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>problemes_tecnics_sermn:20071119_no_acq_hardware</title>
        <link>https://sermn.uab.cat/wiki/doku.php?id=problemes_tecnics_sermn:20071119_no_acq_hardware</link>
        <description>2007-11-19 - No acquisition hardware... ====

Quan s'executa la comanda “a [return]” per anar a la finestra d'adquissició surt un missatge en pantalla,



i en prémer el botó [Details...] surt una pantalla amb la següent informació,


No acquisition hardware available for: 192.168.1.10
(Original message = `NO_ACQUISITION_AVAILABLE1` 192.168.1.10)

====================================================
Mon Nov 19 11:43:41 CET 2007
Topspin Version 1.3 (of March 13 2007)

Could not get URL for ADDRES…</description>
    </item>
    <item rdf:about="https://sermn.uab.cat/wiki/doku.php?id=problemes_tecnics_sermn:20071119_reajust_field">
        <dc:format>text/html</dc:format>
        <dc:date>2007-11-25T20:01:58+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>problemes_tecnics_sermn:20071119_reajust_field</title>
        <link>https://sermn.uab.cat/wiki/doku.php?id=problemes_tecnics_sermn:20071119_reajust_field</link>
        <description>Avance DPX-250 + BACS

2007-11-19 - Canvi del valor de FIELD

S'ha canviat el valor de Field per corregir la lleugera deriva que sembla tenir l'imant. Per fer-ho cal,

	*  introduir una mostra en cloroform deuterat, CDCl3
	*  prémer el botó [FIELD]</description>
    </item>
    <item rdf:about="https://sermn.uab.cat/wiki/doku.php?id=problemes_tecnics_sermn:20080229_canvi_ventiladors">
        <dc:format>text/html</dc:format>
        <dc:date>2009-08-26T11:12:30+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>problemes_tecnics_sermn:20080229_canvi_ventiladors</title>
        <link>https://sermn.uab.cat/wiki/doku.php?id=problemes_tecnics_sermn:20080229_canvi_ventiladors</link>
        <description>2008-02-29 - Canvi de ventiladors

Els ventiladors dels components electrònics dels espectròmetres Avance 250 (autoservei) i Avance-250+BACS (robot) han arribat al final de la seva vida útil, i s'han de canviar.

Tots els ventiladors esmentats en aquesta pàgina són de la marca</description>
    </item>