informatica:hp_z400_600_topspin363_2 [2021/08/19 16:56] miquel [Avance III 600 MHz - Configuració del TopSpin] |
informatica:hp_z400_600_topspin363_2 [2021/08/30 15:29] miquel [Table] |
||
---|---|---|---|
Line 7: | Line 7: | ||
* :ok: expinstall | * :ok: expinstall | ||
* copiar els parameter sets '' | * copiar els parameter sets '' | ||
- | * ::ok: edprosol | + | * :ok: edprosol |
* comprovar si es poden importar els valors de la darrera instal·lació. | * comprovar si es poden importar els valors de la darrera instal·lació. | ||
* :ok: pulse programs | * :ok: pulse programs | ||
Line 286: | Line 286: | ||
Executo la comanda '' | Executo la comanda '' | ||
+ | |||
+ | ===== PENDENT: Configuració del MICS ===== | ||
+ | |||
+ | Comprovo que MICS ha creat els fitxers '' | ||
+ | |||
+ | <WRAP todo> | ||
+ | * Descarregar-se el fitxer BIS de l' | ||
+ | * [[http:// | ||
+ | </ | ||
+ | |||
+ | Les dades de l' | ||
+ | |||
+ | < | ||
+ | $ cat / | ||
+ | ... | ||
+ | ## | ||
+ | --- | ||
+ | ## | ||
+ | ## | ||
+ | ... | ||
+ | ##$OrderNo= < | ||
+ | </ | ||
+ | |||
+ | però quan les entro al formulari per descarregar-me el fitxer BIS, em surt el missatge "BIS file for magnet no 286 / cryostat 5051 not found", | ||
+ | |||
+ | Obro la pàgina ([[https:// | ||
+ | |||
+ | < | ||
+ | BIS file for magnet no 286 / cryostat 5051 | ||
+ | |||
+ | Note: | ||
+ | manually creating a BIS file should be done for OLD systems only (e.g. no BIS available for download). | ||
+ | Do not attempt to use this function for systems with active cooling and/or liquefaction technology! | ||
+ | </ | ||
+ | |||
+ | com que no se'ns aplica, premo el botó < | ||
+ | |||
+ | Llavors s'obre un nou formulari amb un avís, | ||
+ | |||
+ | < | ||
+ | BIS Parameter Definition | ||
+ | |||
+ | This form must be used for NMR magnets only. | ||
+ | |||
+ | Please do this very carefully. | ||
+ | Parameters should be entered based on magnet manual and type label. Entering wrong data might result in erroneous indications and/or false alarms in system monitoring. | ||
+ | </ | ||
+ | |||
+ | Després de llegir l' | ||
+ | |||
+ | ^ Magnet | ||
+ | | Magnet BZH Number | ||
+ | | Frequency | ||
+ | | Cryobore | ||
+ | | Design Letter | ||
+ | | Design Version | ||
+ | ^ Cryostat | ||
+ | | Cryostat Serial | ||
+ | | Dewar Type | D262 | | ||
+ | | RT Bore | ||
+ | ^ Helium | ||
+ | | He Total Volume | ||
+ | | He Holdtime | ||
+ | | He Boil-Off | ||
+ | ^ Nitrogen | ||
+ | | N2 Total Volume | ||
+ | | N2 Holdtime | ||
+ | | N2 Boil-Off | ||
+ | | N2 Vessel Height | ||
+ | ^ Helium Sensor | ||
+ | | Part Number | ||
+ | | Min. Allowed Level | 46 % | | ||
+ | | Min. Level Energizing | ||
+ | | Active Length | ||
+ | ^ He level graph || | ||
+ | | Point1 Level | 0 % | | ||
+ | | Point1 Volume | ||
+ | | Point1 Level | 37 % | | ||
+ | | Point1 Volume | ||
+ | | Point1 Level | 100 % | | ||
+ | | Point1 Volume | ||
+ | ^ Nitrogen Sensor (if present) | ||
+ | | Part Number | ||
+ | | Min. Allowed Level | % | | ||
+ | | Active Length | ||
+ | |||
+ | i premo el botó < | ||
+ | |||
+ | Premo el botó < | ||
+ | |||
+ | |||
+ | |||
+ | ===== PENDENT: Configuració de l' | ||
+ | |||
+ | <WRAP todo> | ||
+ | Documentar la configuració de l' | ||
+ | </ | ||
===== PENDENT: Instal·lació del gestor de llicències CodeMeter ===== | ===== PENDENT: Instal·lació del gestor de llicències CodeMeter ===== |