This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
informatica:hp_z400_600_topspin363_2 [2021/08/30 10:59] miquel t |
informatica:hp_z400_600_topspin363_2 [2021/08/31 10:34] (current) miquel [PENDENT: Instal·lació del gestor de llicències CodeMeter] |
||
|---|---|---|---|
| Line 288: | Line 288: | ||
| ===== PENDENT: Configuració del MICS ===== | ===== PENDENT: Configuració del MICS ===== | ||
| + | |||
| + | Comprovo que MICS ha creat els fitxers '' | ||
| <WRAP todo> | <WRAP todo> | ||
| - | | + | Caldrà afegir/ |
| - | * Descarregar-se el fitxer BIS de l' | + | |
| - | * [[http:// | + | |
| + | * cryoshims anterior | ||
| + | * registre | ||
| + | * registre de recàrregues de LHE | ||
| + | * registre de recàrregues de LIN | ||
| </ | </ | ||
| Line 308: | Line 315: | ||
| </ | </ | ||
| - | però quan les entro al formulari per descarregar-me el fitxer BIS, em surt el missatge "BIS file for magnet no 286 / cryostat 5051 not found", | + | però quan les entro al formulari per descarregar-me el fitxer BIS, em surt el missatge "BIS file for magnet no 286 / cryostat 5051 not found", |
| + | Obro la pàgina ([[https:// | ||
| + | < | ||
| + | BIS file for magnet no 286 / cryostat 5051 | ||
| + | Note: | ||
| + | manually creating a BIS file should be done for OLD systems only (e.g. no BIS available for download). | ||
| + | Do not attempt to use this function for systems with active cooling and/or liquefaction technology! | ||
| + | </ | ||
| + | com que no se'ns aplica, premo el botó < | ||
| + | Llavors s'obre un nou formulari amb un avís, | ||
| + | < | ||
| + | BIS Parameter Definition | ||
| + | |||
| + | This form must be used for NMR magnets only. | ||
| + | |||
| + | Please do this very carefully. | ||
| + | Parameters should be entered based on magnet manual and type label. Entering wrong data might result in erroneous indications and/or false alarms in system monitoring. | ||
| + | </ | ||
| + | |||
| + | Després de llegir l' | ||
| + | |||
| + | ^ Magnet | ||
| + | | Magnet BZH Number | ||
| + | | Frequency | ||
| + | | Cryobore | ||
| + | | Design Letter | ||
| + | | Design Version | ||
| + | ^ Cryostat | ||
| + | | Cryostat Serial | ||
| + | | Dewar Type | D262 | | ||
| + | | RT Bore | ||
| + | ^ Helium | ||
| + | | He Total Volume | ||
| + | | He Holdtime | ||
| + | | He Boil-Off | ||
| + | ^ Nitrogen | ||
| + | | N2 Total Volume | ||
| + | | N2 Holdtime | ||
| + | | N2 Boil-Off | ||
| + | | N2 Vessel Height | ||
| + | ^ Helium Sensor | ||
| + | | Part Number | ||
| + | | Min. Allowed Level | 46 % | | ||
| + | | Min. Level Energizing | ||
| + | | Active Length | ||
| + | ^ He level graph || | ||
| + | | Point1 Level | 0 % | | ||
| + | | Point1 Volume | ||
| + | | Point1 Level | 37 % | | ||
| + | | Point1 Volume | ||
| + | | Point1 Level | 100 % | | ||
| + | | Point1 Volume | ||
| + | ^ Nitrogen Sensor (if present) | ||
| + | | Part Number | ||
| + | | Min. Allowed Level | % | | ||
| + | | Active Length | ||
| + | |||
| + | i premo el botó < | ||
| + | |||
| + | Premo el botó < | ||
| + | |||
| + | Instal·lo i configuro la darrera versió del MICS (2.09i, juny de 2021), i importo el fitxer BIS de l' | ||
| ===== PENDENT: Configuració de l' | ===== PENDENT: Configuració de l' | ||
| Line 328: | Line 396: | ||
| </ | </ | ||
| + | ===== Adreces IP dels mòduls de la consola ===== | ||
| + | |||
| + | <WRAP important> | ||
| + | Aquestes adreces només donen accés als mòduls de la consola si es visiten des de l' | ||
| + | </ | ||
| + | |||
| + | * FIXME [[http:// | ||
| + | * [[http:// | ||
| + | * [[http:// | ||
| + | * [[http:// | ||
| + | * [[http:// | ||
| + | * [[http:// | ||